Medical Device Passivation and Plating in Texas

Surgical instruments, device housings, and diagnostic hardware demand surfaces that are corrosion-resistant, cleanable, and consistent lot after lot. Gleco Plating provides passivation and plating for medical device manufacturers from two Texas plants — Rowlett in Dallas-Fort Worth and McAllen in the Rio Grande Valley — under an ISO 9001:2015 and AS9100D certified quality system with the documentation discipline your supplier audits require.

  • AS9100D
  • ISO 9001:2015
  • ITAR Registered
  • Rowlett & McAllen, TX
Family-owned since 1979 and now in its third generation, Gleco pairs process depth with control: in-house chemists, on-site laboratories at both plants, and operators trained and certified through Gleco University, our internal program with documented competency assessments and recertification requirements. For medical customers, that means the person passivating your instrument components has verifiable, current training records.

Processes for Medical Device Manufacturers

Our processes are RoHS-compliant, applied with lot traceability and certification packages built under an AS9100D-grade quality system.

Why Medical Manufacturers Choose Gleco

FAQ

Medical Passivation and Plating FAQ

Citric or nitric passivation — which should we specify?
Both meet ASTM A967 and AMS 2700 when the correct type and method are called out. Citric is increasingly preferred for safety and environmental reasons and performs well on most 300 and 400 series stainless and PH grades. If your drawing allows either, our chemists will recommend the best fit for your alloy.
How do you verify passivation was effective?
Verification testing per the practice specified on your drawing (per ASTM A967 or AMS 2700) is supported by our on-site laboratories, and results are documented with your certification package.
Can you passivate parts with fine features and lumens?
Yes. Fixturing, solution exchange, rinsing, and drying for small or internal features are defined at contract review and executed by Gleco University certified operators following documented work instructions.
Are you ISO 13485 certified?
We are certified to ISO 9001:2015 and AS9100D. Many medical customers qualify us on the strength of our AS9100D system, lot traceability, and documented operator certification; our quality team can support your supplier audit.
Can you support our passivation process validation?

We supply what a validation package needs from the processor side: the method and type run, solution chemistry and temperature range, immersion time, rinse and dry sequence, and the test used to demonstrate the passive layer. The device manufacturer owns IQ, OQ and PQ; we provide the process record and will run PQ lots to your protocol without changing parameters mid-study. Which method to validate against is covered in citric versus nitric passivation under AMS 2700.

What documentation comes back with a lot?

A certificate naming the specification and revision, the method and type performed, the test used and its result, and the lot identification carried through from your packing list. Records are retained so a lot can be reconstructed after the fact rather than reconstructed from memory. See quality and process control for how those records are held.

How do you keep lots segregated through the line?

Work travels by lot rather than by part number, so two releases of the same part do not merge in one basket, and segregation is physical through the line as well as documented on the traveller. Device passivation runs at our Rowlett plant, where the citric passivation line sits. If your lot sizes are small, say so at quote so they are not consolidated for handling.

We machine 416 and 440C. Which passivation chemistry suits those grades?

Free-machining and high-carbon martensitic grades are the ones that flash-attack in the wrong bath, so the chemistry is chosen for the alloy rather than for the shop’s convenience. Citric chemistry is generally the safer default on those grades; where a drawing insists on nitric passivation, the nitric type matters, because some types carry a dichromate addition specifically to protect those alloys. Put the alloy and heat-treat condition on the print.

Do you plate device components, and how is electroless nickel specified?

Yes, for instruments, housings, fixtures and non-implant hardware. Electroless nickel is specified by phosphorus content and heat-treatment class, and those two choices drive hardness, magnetic response and corrosion behavior far more than thickness does — the types and classes are set out on the ASTM B733 electroless nickel specification page. We do not qualify finishes for implantable use.

Can you gold plate contacts and electrode components?

Yes, over a nickel underplate that blocks base-metal diffusion and reduces porosity in the gold. Gold plating runs at our McAllen plant. Specify purity type, hardness code and thickness class rather than “gold flash”, because those three decide whether the surface survives wear or only survives inspection.

Get a Quote

Submit your drawing, alloy, passivation or plating spec, and quantities through our RFQ form. Our team will confirm requirements and respond with a quote and lead time.
Ready when you are

Not sure which finish your part needs?

Send the print and we’ll tell you. Quotes typically back within one business day, from either plant.

Gleco Plating — Finish Well

Precision metal finishing since 1979. Plating, anodizing, coatings and passivation from three Texas facilities.

Our paint, powder & Cerakote division: Gleco Paint & Powder Coating

  • AS9100D
  • ISO 9001:2015
  • ITAR Registered
  • DFARS Compliant
  • RoHS

Locations

Gleco Rowlett
2220 Grisham Drive
Rowlett, TX 75088
972-475-4300

Gleco McAllen
3800 W. Ursula Ave
McAllen, TX 78503
956-800-4069

info@glecoplating.com

© 2026 Gleco Plating Incorporated. All rights reserved. Privacy PolicyTerms & ConditionsSupplier TermsContact